When to Use Riser vs. Plenum Cables

Summary : Choosing between riser and plenum cables is critical for both fire safety and code compliance. Riser cables suit vertical shafts without airflow, while plenum cables are required in air-handling spaces like ceiling voids. This guide clarifies when to use each type, emphasizing safety, inspection standards, and long-term cost implications for structured cabling installations.

Table of Contents

In structured cabling, performance is not the only consideration. Safety is, as well—and it’s absolute. Whether installing a new office network, retrofitting a warehouse facility, or constructing a data center, cable selection makes all the difference in signal integrity and compliance with fire safety codes that protect people, property, and uptime.

One of the most ill-understood—but essential—cable installation choices is whether to use riser-rated or plenum-rated cable. An incorrect decision can result in failed inspections, rework, and severe liability if a fire occurs.

This guide dispels the uncertainty. When you’ve asked yourself, “Do I need plenum cables here, or will riser do?” we’ll take you step-by-step through the definitive criteria so you can make the correct decision. We’ll divide it by building areas, compliance with local codes, and material-level fire safety, so you can decide wisely and safely.

What Is a Riser?

Let’s start with riser spaces—what they are and why they matter in this discussion.

A riser is any vertical space within a building connecting multiple floors. Think elevator shafts, stairwells, mechanical chases, and conduit paths running from one floor to the next. These are the arteries that carry infrastructure, like water pipes, electrical conduits, and yes, network cables between levels.

What makes riser spaces unique is that they don’t handle air circulation. In other words, if there’s a fire on one floor, the chances of smoke being pulled through a riser by an HVAC system are very low. There may still be fire risk, but the spread of smoke through ventilation is not a primary concern.

What Is Riser Cabling?

Now that you understand the space, let’s talk about the cable.

Riser-rated cables are specifically designed for those vertical runs between floors. Technically known as CMR (Communications Riser), these cables are tested under UL 1666, which measures flame propagation within vertical shafts.

Key features of riser cabling include:

  • Flame-retardant PVC jacket: Designed to resist fire spread in vertical applications.
  • Solid copper conductors: For reliable signal strength over longer distances.
  • Cost-efficiency: Riser cables are more affordable than their plenum counterparts, making them a good fit where higher-grade fire protection isn’t required.

You’ll often find riser-rated cabling used in:

  • Telecom closets connecting floor-to-floor
  • Server rooms that don’t tie into HVAC ducts
  • Apartment buildings or condominiums without open return-air systems

You can’t use riser cables in spaces where air is actively circulated. That’s where plenum cables come in.

What Is a Plenum?

Plenum spaces are often hidden in plain sight. The most common example? The area above your drop ceiling.

In many commercial buildings, the HVAC system uses the ceiling void—or sometimes the floor void—for air return. These plenum spaces allow conditioned air to circulate to the heating or cooling units. But here’s the risk: in a fire, these areas can rapidly move smoke and flames from one part of the building to another.

That’s why plenum spaces are tightly regulated in building and fire codes. Any cable installed in a plenum space must meet much more stringent fire resistance and smoke toxicity standards.

What Is Plenum Cabling?

Plenum-rated cables, marked as CMP (Communications Plenum), are engineered for those air-handling zones where smoke can quickly travel. These cables meet strict standards defined by NFPA 90A and NEC Article 800, both of which require cable jackets that:

  • Limit flame spread
  • Emit low smoke and toxicity
  • Self-extinguishes when the flame is removed

The jacket materials used in plenum cables are often made from FEP (fluorinated ethylene propylene), PTFE (Teflon), or low-smoke PVC blends—substances that burn less aggressively and produce less harmful fumes.

You’ll see plenum-rated cables in:

  • Hospitals, where indoor air quality is critical
  • Universities and public schools
  • Offices with drop ceilings are used as air returns
  • Data centers with underfloor air plenum systems

In essence, any time the cable runs through an air-carrying duct or ceiling, it must be plenum-rated.

Plenum vs. Riser Cables: What's the Difference?

Here’s a side-by-side breakdown of the two cable types for quick reference:

Property

Riser (CMR)

Plenum (CMP)

Fire Rating

UL 1666

NFPA 90A, UL 910

Jacket Material

PVC

FEP, PTFE, Low-smoke PVC

Smoke/Toxicity

Higher

Lower

Use Case

Vertical shafts without airflow

Air-handling spaces like ceilings

Can it Be Used In a Riser?

Yes

Yes

Can it Be Used In a Plenum?

No

Yes

Cost

Lower

Higher

A simple rule of thumb: Plenum cables can always be used in riser spaces, but riser cables can never be used in plenum areas.

Common Acronyms and What They Mean

The cabling world is full of acronyms. Here are the ones that matter most in this context:

  • CMR: Communications Riser – rated for vertical shafts
  • CMP: Communications Plenum – rated for air-handling spaces
  • CL2R / CL3R: Class 2 and 3 riser-rated in-wall cables (for power-limited circuits)
  • CL2P / CL3P: Class 2 and 3 plenum-rated in-wall cables
  • NFPA: National Fire Protection Association – publishes fire safety codes
  • NEC: National Electrical Code – mandates cable ratings and where they must be used

When to Use Which Cable Type

Knowing which cable to use boils down to this: where is it going, and how is air handled in that space?

Use riser cables when:

  • Cabling passes vertically through floors or walls
  • The space is not an air return zone
  • Fire spread risk through airflow is minimal
  • You want a cost-effective solution for closed, dry spaces

Use plenum cables when:

  • The cabling runs through return-air plenums or HVAC ducts
  • The area is shared across zones or needs strict air-quality controls
  • The environment includes public access, such as hospitals or schools
  • You want maximum versatility and future-proof compliance

Default to plenum. Yes, it’s more expensive—but it covers both plenum and riser zones, removes ambiguity, and satisfies the toughest inspections.

Safety and Compliance Are Non-Negotiable

This isn’t just about ticking a box. Using the wrong cable in the wrong zone can lead to:

  • Failed electrical inspections
  • Fire marshal violations
  • Fines or insurance issues
  • Delayed occupancy permits
  • And worst of all, elevated risk during emergencies

Cables don’t just carry data—they’re part of your building’s fire containment strategy. That’s why both plenum and riser ratings exist, and why they’re defined by national codes like the NEC and local AHJs (Authorities Having Jurisdiction).

It’s not a gray area. It’s black and white.

Final Considerations: Cost vs. Risk

It’s tempting to save money on cabling, especially when looking at thousands of feet of cable across multiple floors. However, cost-cutting on the wrong cable type can cost more in the long run.

Plenum cables:

  • They are more expensive up front
  • But they pass more inspections
  • Work across multiple use cases
  • Avoid rework in case HVAC configurations change later

Riser cables:

  • Are budget-friendly
  • But it should only be used where the code allows
  • Must be strictly limited to non-airflow vertical paths

So ask yourself: is a few hundred dollars of savings worth the risk of non-compliance or failed occupancy?

About Network Drops

Network Drops has been working in structured cabling since 1986. Our technicians don’t just pull cable—they bring decades of code knowledge, safety-first installation practices, and hands-on experience in everything from office risers to complex HVAC plenum zones.

We don’t guess. We don’t cut corners. And we don’t leave our clients hanging when the inspector shows up.

Whether it’s a small office upgrade or a large-scale infrastructure build-out, we help you pick the right cable for the right space and ensure it’s done right the first time.

Conclusion: Choose Smart. Choose Safe.

Choosing between riser and plenum cables isn’t just a question of budget or technical specs—it’s a matter of building safety and legal compliance. It’s about protecting people, meeting standards, and installing a network that’s not just fast and stable, but fire-resistant and future-proof.

If you’re planning a network project and aren’t 100% sure what cable your space requires, don’t guess. Reach out to a certified, code-savvy installer at Network Drops. It’ll save you time, money, and risk, and might save lives.

Need help mapping out your cabling plan? Let’s walk the site together.

Installation & Quality Workmanship

Frequently Asked Questions

No. Even if riser cables are inside conduit or enclosed, they still do not meet the strict fire and smoke standards required in plenum spaces. Most inspectors won’t approve it, and you could violate the code. Always use plenum-rated cables in any area used for air circulation.

It’s a code violation—and a serious one. You could fail inspection, delay occupancy, face rework costs, or even void insurance coverage in the event of a fire. More importantly, you’re increasing the risk to life safety in air-handling spaces. It’s not worth the shortcut.

Yes. Plenum-rated cables exceed the fire resistance of riser-rated ones and are fully approved for vertical shaft use. Plenum cables are the safer, more versatile option to simplify ordering or ensure you’re always compliant.

If the area is used for return air—typically above drop ceilings or under raised floors—it’s likely a plenum. You’ll often find these connected to HVAC systems. Consult your building’s mechanical plans or a licensed installer when in doubt. It’s better to verify than assume.

The materials used in plenum jackets—like FEP or low-smoke compounds—are more expensive to produce and test. They’re engineered to resist fire spread and emit less toxic smoke. The higher price reflects the stricter safety standards they’re built to meet.

Request A Quote Today!

"*" indicates required fields

This field is for validation purposes and should be left unchanged.